Atex Explosive area coils


 
  Danfoss solenoid valve coils intended for use in ATEX classified areas. Most Danfoss solenoid valves are available as an ATEX valve solution.
An ATEX approved solenoid valve consists of an ATEX certified coil and a certified valve.
Limitations for ATEX components compared to standard components. The limitations are described below.

Validity:
Approvals are only related to water as fluid. If other fluids are used they must be non-flammable fluids and comply with standard EN 13463-5 § 7.5.5.

Gases:
The valves are produced in materials resistant to most common gases. The user of the valves must secure that the materials used are resistant to the gases applied.

Temperature:
The valves must only be used in systems where the temperature for the pressure medium does not exceed a higher temperature than 60° C. Please see standard EN 982 § 5.3.4.4.1
Danfoss Atex approved coils
The ATEX 94/9/EC directive is one of the “new” European directives. The ATEX directive specifies the requirements for equipment intended for use in potentially explosive atmospheres. ATEX is derived from the French term “ATmosphères EXplosives”.
The ATEX directive replaces the previous EC directive 76/117/EC which only included electrical equipment, whereas ATEX includes both electrical and non-electrical equipment.
Included in the ATEX Directive: -
• Mining and non-mining equipment.
• Explosive atmospheres caused by gas and dust.
• Electrical and non-electrical equipment.
• Equipment (machines, devices, built-in instruments or mobile devices).
• Security systems (equipment which can stop / limit explosions).
• Components (parts without any independent function).
• Security control and regulation devices intended for use outside explosive areas but which secure the equipment in the hazardous areas .

AR, Compact coils for explosive areas
Compact coil for valve range A, EEx m II T4 ATEX 100A Zone 1 approved
• Compact
• Suitable for use installations where flammable liquids are produced, tapped or transported
• Ambient temperature: Up to +55°C
• IP 65 according to IEC 529
• Supplied with 5.5 moulded-on 3-core cable

Code No. Type   Power conn.  Voltage   Voltage     Freq.      Ambient     Coil conn.    Cable        Encl.   Actuator
                                      Watts         [V] a.c.     [V] d.c.     [Hz]        temp. [°C]                      length[m]                 system  
042N5503 AR024D 7,0 W             -            24,00 V       -            -40 - 60 °C    Cable      3,00 m     IP65      9 mm  
042N5505 AR024D 7,0 W             -            24,00 V       -            -40 - 60 °C    Cable      5,50 m     IP65      9 mm  
042N5515 AR024D 4,8 W             -            24,00 V       -            -40 - 60 °C    Cable      5,50 m     IP65      9 mm  
042N5533 AR230C 6,0 W           230 V        -          50/60 Hz   -40 - 60 °C     Cable     3,00 m     IP65      9 mm  
042N5535 AR230C 6,0 W           230 V        -          50/60 Hz   -40 - 60 °C     Cable     5,50 m     IP65      9 mm


BO, High performance coils for explosive areas
Suitable for explosive areas for valve range B, 10 W ac/dc, EEx m II T4 ATEX 100A Zone 1 approved
• Suitable for explosive areas (zone 1)
• Encapsulated coils with long operation life
• Ambient temperature: Up to +40°C
• Medium temperature: Up to +90°C
• IP 67 for moist environments with flying lead
• Seal kit for extremely wet or aggressive environments available

Code No. Type   Power conn.  Voltage   Voltage     Freq.      Ambient     Coil conn.    Cable        Encl.   Actuator
                                      Watts         [V] a.c.     [V] d.c.     [Hz]        temp. [°C]                      length[m]                 system  
018Z6591 BO240C 10,0 W        240 V          -          50/60 Hz  -20 - 40 °C    Cable       5,00 m      IP67  13.5 mm   
018Z6592 BO230C 10,0 W        230 V          -          50/60 Hz  -20 - 40 °C    Cable       5,00 m      IP67  13.5 mm  
018Z6593 BO110C 10,0 W        110 V          -          50/60 Hz  -20 - 40 °C    Cable       5,00 m      IP67  13.5 mm  
018Z6594 BO048C 10,0 W          48 V          -          50/60 Hz  -20 - 40 °C    Cable       5,00 m      IP67  13.5 mm  
018Z6595 BO024C 10,0 W          24 V          -          50/60 Hz  -20 - 40 °C    Cable       5,00 m      IP67  13.5 mm  
018Z6596 BO024D 11,0 W            -          24,00 V        -           -20 - 40 °C    Cable       5,00 m      IP67  13.5 mm

BP, High performance coils for explosive areas
Compact, suitable for explosive areas, for valve range B, 16 W dc, EEx m II T4 ATEX 100A Zone 1 approved
• Suitable for explosive areas (Zone 1)
• Encapsulated coils with long operation life
• Ambient temperature: Up to +55°C
• Medium temperature: Up to +90°C
• IP 67 for moist environments with moulded-in 3-core cable
• Seal kit for extremely wet or aggressive environments available

Code No. Type   Power conn.  Voltage   Voltage     Freq.      Ambient     Coil conn.    Cable        Encl.   Actuator
                                      Watts         [V] a.c.     [V] d.c.     [Hz]        temp. [°C]                      length[m]                 system  
018Z6623 BP024D 10,5 W           -          24,00 V        -          -40 - 60 °C    Cable        3.00 m       IP67  13.5 mm  
018Z6653 BP230A 12,0 W         230V          -           50 Hz     -40 - 60 °C    Cable        3.00 m       IP67  13.5 mm

Other Danfoss ATEX Controls

Pressure Control type MP 55E II 3 G EEx nL IIC T6
The differential pressure controls are suitable for use in installations located in potentially explosive atmospheres.
• ATEX Category 3 (Zone 2).
• Grade of enclosure: IP 20.
• Max working pressure PS = 17 bar.
• ATEX design
• Gold contactors.
• Stainless steel bellow with restricted movement.
• Soldering connection.
NOTE: Contact loads - Must be used with reliable means of limiting the voltage and current to prevent sparks between

Pressure Control type KPE II 3 G EEx nL IIC T6
The pressure controls are suitable for use in installations located in potentially explosive atmospheres.
• ATEX Category 3 (Zone 2).
• Grade of enclosure: IP 30 or IP 40
• Max working pressure: KP 1E: PS = 8 bar.
• KP 7E: PS = 32 bar
• ATEX design
• Gold contactors.
• Stainless steel bellow with restricted movement.
• Soldering connection.
NOTE: Contact loads - Must be used with reliable means of limiting the voltage and current to prevent sparks between the contact surfaces. This could be zener diodes or Ex barriers.

Pressure Transmitter Type MBS 4201 II 1 G EEx ia IIC T4 – T6
The pressure transmitters are suitable for use in installations located in potentially explosive atmospheres.
• ATEX Category 1 (Zone 0).
• Grade of enclosure: IP 65 / IP67.
• Measuring range 0 - 600 bar.
NOTE: Must be used in conjunction with safety barriers

RT- pressure and temperature controls II 2 G EEx ia IIC T6
The RT- pressure and temperature controls are suitable for use in installations located in potentially explosive atmospheres.
• ATEX design
• ATEX Category 2 (Zone 1)
• Grade of enclosure IP 67
• Gold contactors
• Stainless steel bellow with restricted movement
• Stainless steel frame (conductive)
NOTE: Contact loads - Must be used with reliable means of limiting the voltage and current to prevent sparks between the contact surfaces. This could be zener diodes or Ex barriers.

For full technical details on all Danfoss products visit  http://www.mandmcontrols.co.uk/danfoss

 
   
     
 
  Home | About Us | Delivery Rates | Sitemap | Contact Us | Solenoid Valves  
       
  M & M Controls, Unit 55, Ardent Way, Mountheath Ind. Est. George Street, Prestwich, Manchester, M25 9WE
Tel: +44 (0)161 798 0783 Fax: +44 (0)161 773 7869 Email: info@mandmcontrols.com
Copyright M & M Controls 2009. All rights reserved  
   
* Data Sheets * 018F0091 Test magnet * ASCO Numatics * Asco SCE210C94 * Asco Solenoid Valves
* Atex Explosive area coils * AV210 Angle seat valves * AVTA Thermostatic valves * AVTB Thermostatic Valves * CI 4 to CI5 Conversion
* CI 6-50 Contactors * CS Compressor Switches * Danfoss CI9 Contactors * Danfoss Contactor Range * Danfoss Controls
* Danfoss Distributor * Danfoss District Heating * Danfoss EV220B EVSI * Danfoss Marine Controls * Danfoss Marine Transmitters
* Danfoss Motor Controls * Danfoss Nessie * Danfoss Nessie Coils * Danfoss Pressure Sensors * Danfoss Pressure Transmitter
* Danfoss Refrigeration * Danfoss Relay Overloads * Danfoss Solenoid Valves * Danfoss Thermostats * Danfoss Timers
* Danfoss Transducers * Danfoss UK - About * Danfoss UL NPT Valves * Danfoss UL recognised coils * Danfoss Valves
* Danfoss Wind Power * EMP2 Transmitter * EV225B Steam valves * EV260B Proportional valve * Food Temperature Sensors
* High Pressure Solutions * Industrial Automation * Joucomatic * KP - KPI Switches * KPS Switches - Thermostats
* M&M Controls * MBC 5100 Pressure switch * MBC Marine Switches * MBS1250 Pressure Transmitter * MBS3000 Transmitters
* MBS3250 Transmitter * MBS8200 - MBS8250 Series * MBT Temperature Sensors * Mobile Industrial Hydraulics * Nessie Fire Fighting
* Pressure Switch Pressostat * RT Switches-Thermostats * Seawater Pressure Switches * Ship Approved CAS Switches * WRAS Solenoid valves
     
Technical Danfoss Coils
Site by Split Graphics Web Design Manchester